Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive viscoelastic agent.

1999

Cataract surgery and intraocular lens (IOL) implantation in pediatric eyes remain controversial. Using a viscoadaptive viscoelastic agent, we implanted a modified capsular bending ring (CBR) as well as an acrylic IOL with a sharp-optic-edge design in the capsular bag. All operated eyes demonstrated a low postoperative inflammatory reaction and a clinically well-centered IOL. The band-shaped, sharp-edged CBR facilitates the creation of a sharp, discontinuous bend in the equatorial capsule, which prevents anterior and posterior capsule opacification. Combining the viscoadaptive viscoelastic agent and the CBR enhances the safety of primary and secondary posterior chamber IOL implantation in pe…

Capsule Opacificationmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentLens Capsule CrystallineIntraocular lensBiocompatible MaterialsCataract ExtractionProsthesis ImplantationLens Implantation IntraocularOphthalmologymedicineHumansPolymethyl MethacrylateHyaluronic AcidChildPosterior capsule opacificationLenses Intraocularbusiness.industryCapsuleCataract surgeryeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeCapsular bagSurgerysense organsbusinessPediatric cataractFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Closed foldable capsular rings

2004

A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.

Lens capsulemedicine.medical_specialtyPhacoemulsificationMaterials sciencePolymethyl methacrylatemedicine.medical_treatmentForcepsLens Capsule CrystallineCapsuleProstheses and ImplantsPhacoemulsificationAnatomyCataractSensory SystemsProsthesis ImplantationOphthalmologyPostoperative ComplicationsOphthalmologymedicineHumansPolymethyl MethacrylateSurgeryPosterior capsule opacificationJournal of Cataract and Refractive Surgery
researchProduct

General Applications of Viscoelastics

2000

The many and diverse physicochemical characteristics of viscoelastic substances impose both their desired and undesired effects clinically. As there is no single ideal substance to meet clinical stipulations, individual viscoelastic characteristics should be considered with respect to demand. Georg Eisner described viscoelastic agents as a tool for space-occupying measures (in tissues, in space or on surfaces) applied by the use of special techniques (Eisner, 1980; Eisner, 1983). In surgery, viscoelastic substances protect tissues and cells from mechanical trauma, serve to separate tissues, occupy space, break away adhesions, stop bleeding, coat, act as manipulative instruments and move tis…

Viscoelastic SubstancesComputer sciencePosterior capsule opacificationBiomedical engineering
researchProduct

Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

2014

The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests performed in different ocular locations for the diagnosis and follow-up of ocular disease, like macular and optic nerve diseases. Some parameters measured by visual field examinations, scanning laser polarimetry, and optical coherence tomography (OCT) have changed after PCO removal. Imaging quality a…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentOptic DiskScanning laser polarimetryGlaucomalcsh:MedicineReview ArticleDiagnostic Techniques OphthalmologicalRetinaGeneral Biochemistry Genetics and Molecular BiologyOptical coherence tomographyOphthalmologymedicineHumansPosterior CapsulotomyRetinaGeneral Immunology and Microbiologymedicine.diagnostic_testPosterior Capsulotomybusiness.industrylcsh:RGeneral MedicineCapsule Opacificationmedicine.diseaseeye diseasesVisual fieldmedicine.anatomical_structureCapsulotomysense organsbusinessOptic discBioMed Research International